What Is ANSI/AAMI ST108:2023 and Why Is It Important?

ANSI/AAMI ST108:2023, Water for the Processing of Medical Devices, establishes requirements and guidance for selecting, producing, distributing, monitoring and maintaining water used in medical-device processing. It gives healthcare facilities a structured framework for managing water quality at the point of use during cleaning, rinsing, disinfection and sterilization.

Laboratory pipette dispensing a water sample into rows of glass vials for water quality testing

Why Water Quality Matters in Sterile Processing

Water contacts instruments, washers, ultrasonic equipment, steam systems and other critical components throughout medical-device processing. Unsuitable water can contribute to deposits, staining, corrosion, equipment damage, inconsistent cleaning performance and operational interruptions.

ST108 helps facilities connect water quality to patient safety, device integrity, equipment reliability and process control. It also moves water management beyond a one-time equipment purchase by emphasizing responsibilities, monitoring, maintenance and continuous improvement.

The Three Water Categories in ST108

CategoryWhat It IsTypical Uses
Utility waterIncoming supply, possibly treated at the facility for the intended useFlushing, washing and intermediate rinsing
Critical waterWater from a multi-step treatment process that may include pretreatment, RO and/or DI, storage, distribution and final treatmentFinal rinsing; may feed steam generation depending on the system and process requirements
SteamVaporized water from a central boiler or local steam generator or heat exchangerSterilization — source-water quality and the delivery system affect steam purity and performance
The three water categories in ANSI/AAMI ST108:2023 — utility water, critical water and steam — with their typical uses in medical device processing

ST108 Is a Water-Management Program, Not Just an RO Specification

A facility should not assume that installing an RO automatically addresses every ST108 responsibility. The standard includes water-quality selection, roles and responsibilities, treatment-system qualification, storage and distribution, monitoring, bacterial-control strategies, troubleshooting, maintenance and quality improvement.

The treatment system must be designed around the facility’s incoming water, equipment instructions for use, point-of-use requirements, demand profile and risk assessment. Distribution piping, storage turnover, temperature, stagnation, sampling locations and maintenance practices can be as important as the primary treatment equipment.

For Texas hospitals and surgery centers, the incoming-water side of that design is local by nature: hard, alkaline supplies common across North and Central Texas place different demands on pretreatment and RO design than the variable blended surface water many Gulf Coast facilities receive. The point-of-use requirements come from the standard; the treatment train that meets them starts from your city’s water.

A Practical ST108 Preparation Process

  1. Form the water-management team and assign clear responsibilities.
  2. Map every use of water and steam in medical-device processing.
  3. Review equipment manufacturers’ instructions for use and identify the required water category at each step.
  4. Test incoming water and water at representative points of use.
  5. Compare results with the applicable ST108 requirements and identify gaps.
  6. Evaluate pretreatment, primary treatment, storage, distribution and final treatment.
  7. Create operating limits, alarm points, sampling schedules, maintenance procedures and corrective-action plans.
  8. Document qualification, routine monitoring, service and quality-improvement activities.
  9. Plan for interruptions, boil-water advisories, treatment failures and other emergency conditions.

Treatment Technologies That May Be Used

The exact treatment train depends on the source water and point-of-use target. It may include sediment filtration, activated carbon, water softening, reverse osmosis, deionization, UV disinfection, final membrane filtration, storage and a recirculating distribution loop.

Material compatibility, sanitization method, tank design, recirculation velocity, temperature and monitoring should be evaluated as an integrated system. A qualified team should review the complete design rather than selecting individual components independently.

Questions Healthcare Facilities Should Ask

  • Do we know the quality of water at each point of use—not only at the building entrance?
  • Are our required water categories aligned with each device and processing step?
  • Can our storage and distribution system maintain water quality between the treatment equipment and the department?
  • Do we have defined monitoring limits and a documented response when a limit is exceeded?
  • Can the system be sanitized and serviced without creating unacceptable disruption?
  • Do we have adequate capacity and redundancy for peak processing demand?

How Culligan Texas Can Support ST108 Planning

Culligan Texas can assist healthcare facilities across Texas with water testing, treatment-system assessment, equipment selection, RO and DI design, pretreatment, storage, distribution and ongoing service. We work with facility stakeholders and contractors to develop water treatment solutions around the site’s source water, demand and project requirements.

Important: This page is an educational overview and is not a substitute for purchasing and reviewing the complete ANSI/AAMI ST108:2023 standard, applicable regulations, accreditation requirements, equipment instructions for use or advice from the facility’s clinical, infection-prevention, engineering and compliance teams.

Frequently Asked Questions

What is ANSI/AAMI ST108:2023?

It is the American National Standard titled Water for the Processing of Medical Devices. It addresses water quality delivered to the point of use for cleaning, rinsing, disinfection and sterilization.

Did ST108 replace AAMI TIR34?

ST108 revises and supersedes AAMI TIR34:2014/(R)2021 and establishes a national standard rather than a technical information report.

What are the water categories in ST108?

The standard identifies utility water, critical water and steam, with use and quality considerations for medical-device processing.

Does installing reverse osmosis make a facility compliant?

Not by itself. Treatment equipment is one part of a broader program that includes water-quality selection, distribution, monitoring, maintenance, documentation and corrective action.

Where should water be tested?

Testing should be planned around incoming water, treatment stages and representative points of use. The facility’s water-management team should establish locations and frequencies using the standard and its risk assessment.

Can Culligan Texas certify ST108 compliance?

Culligan Texas can provide testing, design, equipment and service support, but the healthcare facility is responsible for its overall program, validation, documentation and compliance decisions.